PRORend EIFS Insulation

Insulation

ProRend EIFS can be installed using either expanded polystyrene (EPS), or mineral wool insulations.

Both boast superb green properties:

  • CFC / HCFC free
  • Zero Ozone Depletion Potential (ODP) rated
  • Zero Global Warming Potential (GWP) rated


 

Mineral Wool

EPS


 

Slab

Lamella

70 White

70 Platinum

200 White

Technical properties  

Thermal conductivity λ10, W/mK

0.036

0.040

0.037

0.030

0.033

Water vapour permeability, µ
(BS EN ISO 10456 2007 Table 4)

1/1

1/1

60/60

60/60

60/60

Fire classification

A1

A1

E †

E †

E †

Nominal density, kg/m³

126 - 140

126 - 140

14 - 16

14 - 16

30 - 32

  † Contains fire retarding additive

Insulation panel properties

Blunt edge

Thickness, mm

30 - 200

30 - 300

20 - *

20 - *

20 - *

Face, l x h, mm

1000 x 500

1000 x 200

1000 x 500

1000 x 500

1000 x 500

Rail edge

Thickness, mm

40 - 160

no

40 - *

40 - *

40 - *

Face, l x h, mm

500 x 500

no

500 x 500

500 x 500

500 x 500

Tongue and groove

Thickness, mm

no

no

40 - *

40 - *

40 - *

Face, l x h, mm

no

no

1050 x 550

1050 x 550

1050 x 550

Bends around curved walls

no

yes

no

no

no

 

 

 

 

* Size limit in excess of 1000mm

Note insulation panel thicknesses increase in 10mm increments

Bespoke EPS shaped panels are available on request e.g. columns and decorative details

U Values And Dew Points

U values are a measure of the amount of heat conducted through a material per m² at a given temperature. The lower the U value the less heat that will be lost through the walls.

A dew point is the temperature at which air becomes saturated: below this point moisture is deposited as condensation.

Properties constructed using external wall insulation are able to force the dew point to the outside of the wall.

The SAS technical team will provide you with a U-value and dew point calculation once you have provided us with the makeup of the wall.

Expanded Polystyrene, EPS

ProRend EIFS EPS insulation manufactured to BS 13163: 2001 is available in 3 grades:

  • EPS 70 White - standard insulation with highest (poorest) thermal conductivity
  • EPS 70 Platinum - premium insulation with the best thermal conductivity of all insulants sold as part f the ProRend EIFS

Achieving a U-value of 0.24 on a traditional cavity wall renovation could save you 20mm in thickness of insulation compared with EPS 70 White or Mineral Wool slab saving on transport costs and sundry tems such as fixings and beading profiles

  • EPS 200 White - dense insulation ideally suited to application below DPC

Mineral Wool

ProRend EIFS Mineral Wool insulation is available in 2 grades

  • Slab - best thermal conductivity of mineral wool insulants
  • Lamella - available in widest range of thicknesses and suitable for curved walls

Mineral Wool can be used as a sole insulant in ProRend EIFS projects or to serve as a fire barrier in EPS type construction. Mineral Wool fire barriers are typically used as follows:

  • ProRend EIFS adhesive EPS constructions using Mineral Wool Lamella
  • ProRend EIFS rail EPS constructions using Mineral Wool Rail Slab

For further details on fire barriers refer to adhesive system or rail system respectively

How much insulation do I require?

This varies on a case by case basis and dependent upon which insulation is chosen. Contact our technical team and we can work with you to specify the right insulation for your project.

Sample U-value Calculation

† U value calculations according to BS EN ISO 6946

Adhesive system renovation over typical rendered brickwork cavity wall using 70mm EPS Platinum

Construction Thickness. m Lambda. W/mK R.m²K/W
External Resistivity     0.04
ProRend Colourtex 0.0015 0.700 0.00
ProRend Lite 0.0050 0.270 0.22
Prorend EIFS EPS 70 Platinum 0.0700 0.030 2.33
ProRend Lite 0.0050 0.270 0.02
BS EN 12524 Rend, Lime, Sand 0.0200 0.800 0.03
Brick Outer Leaf 0.1020 0.770 0.13
Cavity 0.0400 0.222 0.18
Brick Inner Leaf 0.1020 0.560 0.18
BS EN 12524 Gypsum Plastering 0.0150 0.570 0.03
Internal Resistivity     0.13
  0.3605   Rτ = 3.09m²K/W
      U = 0.32W/m²K

Rail system new build over lightweight steel constructed walls using 130mm Mineral Wool Slab

Construction Thickness. m Lambda. W/mK R.m²K/W
External Resistivity     0.04
ProRend Colourtex 0.0015 0.700 0.00
ProRend Lite 0.0050 0.270 0.02
Prorend EIFS Mineral Wool Slab 0.1300 0.036 3.61
BS EN ISO 6946 Cavity 0.0150 0.088 0.17
BS EN 12524 Sheathing Board 0.0090 0.130 0.07
Metal Frame 0.1000 0.556 0.18
Plasterboard 0.0125 0.210 0.06
Plasterboard 0.0125 0.210 0.06
BS EN 12524 Gypsum Plastering 0.0030 0.570 0.01
Internal Resistivity     0.13
  0.2885   Rτ = 4.35m²K/W
      U = 0.23W/m²K